High density, double-conversion on-line power protection with scalable runtime.
|
---|
provided equipment |
CD with software
Rack mounting support rails Smart UPS signalling RS-232 cable User manual Web/SNMP management card |
|
---|---|---|
performance multiplier |
1
|
|
Number of tare power |
175 W
|
|
Number of power module free slots |
0
|
|
Number of power module filled slots |
0
|
|
redundant |
No
|
|
size UPS version |
Internetworking
Server Telecom |
|
UPS size |
S
|
|
value multiplier |
1
|
number of rack unit |
12U
|
|
---|---|---|
colour |
Black
|
|
depth |
77.3 cm
|
|
height |
53.3 cm
|
|
mounting location |
Front
|
|
mounting preference |
Lower
|
|
product weight |
247.73 kg
|
|
mounting mode |
Rack-mounted
|
|
two post mountable |
0
|
|
USB compatible |
No
|
|
width |
43.2 cm
|
network frequency |
40…70 Hz auto-sensing
|
|
---|---|---|
number of input connectors |
1 hard wire 3-wire (1P + N + E)
1 hard wire 5-wire (3P + N + E) |
|
input voltage limits |
160…280 V
|
|
Input voltage |
220 V
240 V |
|
maximum input current |
90 A
|
|
switching current capacity |
100 A
|
|
input harmonic distortion |
Less than 5 % for full load
|
|
input current |
90 A (1 phase)
30 A per phase (3 phases) |
|
input voltage |
230 V
400 V 3 phases |
|
load power factor |
0.8
|
|
cos phi |
0.95
|
rated power in W |
12000 W
|
|
---|---|---|
Maximum configurable power in W |
12000 W
|
|
harmonic distortion |
Less than 5 %
|
|
output frequency |
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains
|
|
Output voltage |
220 V
240 V |
|
crest factor |
3 : 1
|
|
UPS type |
Double conversion online
|
|
Wave type |
Sine wave
|
|
output connector type |
Hard wire 3-wire (H N + E) 1
Hard wire 5-wire (3P + N + E) 1 |
|
nb of power socket outlets |
2 IEC Jumpers
8 IEC 60320 C19 |
|
output overload operation |
60 seconds at 125% and 30 seconds at 150%
|
|
bypass type |
Built-in static bypass
Internal bypass (automatic and manual) Optional external bypass |
|
curve equation |
Efficiency
|
|
curve fixed loss |
0.017
|
|
curve load maximum |
100 %
|
|
curve load minimum |
2 %
|
|
curve proportional loss |
0
|
|
curve square loss |
0.036
|
|
curve X-axis maximum |
100 %
|
|
curve test cond ID |
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output.
|
|
curve X-axis minimum |
0 %
|
|
curve X-axis title |
Load
|
|
curve X-axis units |
Percentage
|
|
curve Y-axis maximum |
100 %
|
|
curve Y-axis minimum |
50 %
|
|
curve Y-axis title |
Efficiency
|
|
curve Y-axis units |
Percentage
|
|
efficiency |
93 % (in battery operation)
|
|
graph display |
1
|
|
output voltage |
230 V
|
|
Maximum configurable power in VA |
15000 VA
|
|
rated power in VA |
15000 VA
|
product certifications |
VDE
|
|
---|---|---|
standards |
EN/IEC 62040-2
EN/IEC 62040-1-1 |
ambient air temperature for operation |
0…40 °C
|
|
---|---|---|
relative humidity |
0…95 % non-condensing
|
|
operating altitude |
0…10000 ft
|
|
ambient air temperature for storage |
-15…45 °C
|
|
storage Relative Humidity |
0…95 % Non-condensing
|
|
storage altitude |
0.00…15240.00 m
|
|
acoustic level |
50 dBA
|
|
heat dissipation |
2800 Btu/h
|
|
show note OP temperature |
No
|
|
IP degree of protection |
IP20
|
battery type |
Lead-acid battery
|
|
---|---|---|
number of battery filled slots |
4
|
|
number of battery free slots |
0
|
|
Battery recharge time |
2.5 h
|
|
number of battery replacement quantity |
4
|
|
additional information |
Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
|
|
liquid value |
0
|
|
battery voltage |
+/- 192 V (split battery referenced to neutral)
|
|
battery curve |
C
|
|
battery charger power |
1530 W rated
|
|
Battery power in VAH |
3840 VAh runtime
|
|
battery life |
3…5 year(s)
|
|
battery option |
SURT192RMXLBP2 1 7680 VAh
SURT192RMXLBP2 2 11520 VAh SURT192RMXLBP2 3 15360 VAh SURT192RMXLBP2 4 19200 VAh SURT192RMXLBP2 5 23040 VAh SURT192RMXLBP2 6 26880 VAh SURT192RMXLBP2 7 30720 VAh SURT192RMXLBP2 9 38400 VAh |
|
extended runtime |
1
|
free slots |
0
|
|
---|---|---|
preinstalled device |
Network management card 2 with environmental monitoring
|
|
control panel |
Multifunction LCD status and control console
|
|
alarm |
Audible and visible alarms : configurable delays
|
|
Emergency power off |
Yes
|
noise suppression |
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
|
---|
Package 1 Weight |
314.09 kg
|
|
---|---|---|
Package 1 Height |
99 cm
|
|
Package 1 width |
61 cm
|
|
Package 1 Length |
100.3 cm
|
|
Number of Units in Package 3 |
1
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
REACh Regulation | ||
EU RoHS Directive |
Compliant
EU RoHS Declaration |
|
Mercury free |
Yes
|
|
RoHS exemption information | ||
Environmental Disclosure | ||
Circularity Profile | ||
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
|
Optimized Energy Efficiency |
Energy efficient product
|
|
Take-back |
Take-back program available
|
Warranty |
2 years repair or replace
|
---|